VOC
Fast response of VOC gas leakage with a high efficient pump inside
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Low concentration VOC gas detection by PID sensor
Stable quality and proved detection principle for service life
Fine LCD display for showing various information
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring by RS-485 Modbus or PoE
2-stage alarm, 1-trouble display and relay contact output
3-wire connection for signal & power
Calibration and maintenance by one-man
EX
Fast response of flammable gases leakage with a high efficient pump inside
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Detection gas from low to high concentration owing to various detection principle
Stable quality and proved detection principle for service life
Fine LCD display for showing various information
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring by RS-485 Modbus or PoE
2-stage alarm, 1-trouble display and relay contact output
3-wire connection for signal & power
Calibration and maintenance by one-man
TX
Fast response of toxic gases & Oxygen leakage with a high efficient pump inside
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Stable quality and proved detection principle for service life
Superior performance for detecting toxic gases below TLV
Fine LCD display for showing various information
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring system by RS-485 Modbus communication or PoE
2-stage alarm, 1-trouble display and relay contact output
3-Wire Type
Calibration and maintenance by one-man
IR
Application of anti-malfunction algorithm to interference gas (Ethanol, FC-3283, IPA)
Fast response speed by applying new infrared measurement principle
Built-in high-performance pump to detect gas leakage quickly
Built-in automatic flow control with flow sensor
Built-in self-diagnosis function
Application of proven detection principle with stable quality and service life
Color graphic 1: 1 interactive parameter setting using LCD
4-20mA (Current source or Sink) output
Easy to install monitoring system by RS-485 Modbus and PoE communication
Two-stage alarm, one fault indication and relay contact output
Built-in Data & Event log function
Calibration and maintenance by one-man