Continuous detection of VOC gas in explosion hazardous area with flame proof structure
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Fast response of gas leakage with a high efficient pump inside
Low concentration VOC gas detection by PID sensor
Stable quality and proved detection principle for service life
Auto calibration and program setting with a magnet bar
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring by RS-485 Modbus
3-wire connection for signal & power
2-stage alarm, 1-trouble display and relay contact output
Calibration and maintenance by one-man
EX
Continuous detection of flammable gases in explosion hazardous area with flame proof structure
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Fast response of VOC gas leakage with a high efficient pump inside
Detection gas from low to high concentration owing to various detection principle
Stable quality and proved detection principle for service life
Auto calibration and program setting with a magnet bar
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring system by RS-485 Modbus communication
3-wire connection for signal & power
2-stage alarm, 1-trouble display and relay contact output
Calibration and maintenance by one-man
TX
Continuous detection of toxic gases and oxygen in explosion hazardous area with flame proof structure
Self diagnosis function with built-in Microprocessor
Easy replacement with a cartridge type sensor
Digital flow sensor to maintain regular flow rate
Fast response of gas leakage with a high efficient pump inside
Stable quality and proved detection principle for service life
Excellent selectivity by adapting detection principle only for toxic gases & oxygen
Superior performance for detecting gases below TLV
Auto calibration and program setting with a magnet bar
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring system by RS-485 Modbus communication
3-Wire Type
2-stage alarm, 1-trouble display and relay contact output
Calibration and maintenance by one-man
IR
Continuous detection of flammable, CO2, CO and N2O gas in explosion hazardous area with flame proof structure
State-of-the art infrared detection principle
Operation in non oxygen environment
Digital flow sensor to maintain regular flow rate
Fast response detection of gas leakage with a high efficient pump inside
Self diagnosis function with built-in Microprocessor
Fast response time(<6 sec)
Stable quality and proved detection principle for service life
Auto calibration and program setting with a magnet bar
4-digit digital gas concentration display
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring system by RS-485 Modbus communication
3-Wire Type
2-stage alarm, 1-trouble display and relay contact output